D17
PHYSICAL POTESTAS | TEST METHOD | UNIT | TYPICAL DATA |
Obturaculum Material | / | / | HDPE |
Plug Colore | / | / | album |
Membrana Construction | / | / | PTFE/PO non texta |
Superficies membrana Property | / | / | Oleophobic & Hydrophobic |
Typical Aeris O Rate | ASTM D737 | ml/min @ 7KPa | 1400 |
Aqua Entry Pressura | ASTM D751 | KPa 30 sec | ≥70 |
IP Gradus | IEC 60529 | / | IP67/IP68 |
Humor Vapor Transmission | ASTM E96 | g/m2/24h | >5000 |
Oleophobic Gradus | AATCC 118 | Gradus | ≥7 |
Service Temperature | IEC 60068-2-14 | ℃ | -40℃~ 125℃ |
ROHS | IEC 62321 | / | Occursum ROHS Requirements |
PFOA & PFOS | US EPA 3550C & US EPA8321B | / | PFOA & PFOS Free |
Haec membranarum series adaequare potuit impressionem differentialium vasorum chemicorum, quae per differentiam caliditatem, altitudinem mutationes et vapores consumendi solvebant, ut deformatio continentis et liquidi lacus impedirent.
Membranae adhiberi possunt in obturaculis spirabilibus lineris et spirabilibus pro vasis oeconomiae pacandis, et aptae sunt ad summam intentionem Hazardous Chemicals, Humilis-contentio Familiaris Chemicals, Chemicals Agricultural et alia Chemicals Specialia.
Shelf vita quinque annos a die acceptitionis huius producti est, quamdiu hoc productum in suo originali packaging in ambitu sub 80° F (27°C) et 60% RH conditum est.
Omnia supra data sunt typica notitia materiae ad membranam rudis, ad solam referentiam, et non debet adhiberi ut speciales notitias qualitatum praetereuntium.
Omnes technicae informationes et consilia hic posita in Aynuo praecedentibus experimentis et experimentis eventis innituntur.Aynuo hoc dat notitiae optimae suae cognitionis, sed nullum iuris officium assumit.Customers rogantur ut idoneitatem et usbilitatem in applicatione specifico reprimant, quandoquidem operis effectus iudicari tantum potest, cum omnia necessaria operativae notitiae praesto sunt.